176                       Applied Process Design for Chemical and Petrochemical Plants


























                                                                                            TANK
                                                                         (1.5-2  GPM/       25 GALLON
                                                                         PROCESS            (LOW  MINERAL
                                      PUMP SEAL  HOUSING                 PUMP)              OR OTHER
                                                                                            ACCEPTABLE  LOW
                                  -
                                                                                            VISCOSITY OIL)
                                      Figure 3-31A. Typical seal flush arrangement for double mechanical seals.





                                                PLANT VENT
                                                HEADERSYS




                                T           FLUSH  GLAs?n
                                                    'IGHT
                                      '2                                            SEAL OIL SUPPLY TANK
                                                                                    2-3
                                                                                        GAL.
                                                                                             CAPACITY
                 DISCHARGE
                 PIPE FROM
                 PUMP


                                                                                    PUMPING RING IN SEAL


                                PUMP  END                                      DRIVE END
                                                                           T-      LOW PRESSURE SEAL (OUTSIDE)






                                         lNSIBE SEAL/     PUMP SEAL  HOUSING
                                      Figure 3-31B. Typical seal flush arrangement for tandem mechanical seals.