Page 203 - APPLIED PROCESS DESIGN FOR CHEMICAL AND PETROCHEMICAL PLANTS, Volume 1, 3rd Edition
P. 203
176 Applied Process Design for Chemical and Petrochemical Plants
TANK
(1.5-2 GPM/ 25 GALLON
PROCESS (LOW MINERAL
PUMP SEAL HOUSING PUMP) OR OTHER
ACCEPTABLE LOW
-
VISCOSITY OIL)
Figure 3-31A. Typical seal flush arrangement for double mechanical seals.
PLANT VENT
HEADERSYS
T FLUSH GLAs?n
'IGHT
'2 SEAL OIL SUPPLY TANK
2-3
GAL.
CAPACITY
DISCHARGE
PIPE FROM
PUMP
PUMPING RING IN SEAL
PUMP END DRIVE END
T- LOW PRESSURE SEAL (OUTSIDE)
lNSIBE SEAL/ PUMP SEAL HOUSING
Figure 3-31B. Typical seal flush arrangement for tandem mechanical seals.