8.6. TYPES  OF  HEAT  EXCHANGERS  193



                    8.6
             EXAMPLE                                          Find 11 from the chart. Tube length, L = AJ0.2021  ft.
             Sizing an Emhanger with Radial Finned Tubes
          A liquid is heated from 150 to 190°F with a gas that goes from 250    ~  x  Q   A  ,  L   .
          to 200°F.  The  duty is  1.25MBtu/hr. The inside film  coefficient is
                                                                               26  1.149 0.59 121.8 602
          200, the  bare  tube outside coefficient is h, = 20 Btu/(hr)(sqft)("F).   Steel   60  0.756 0.76  96.5  477
                                                                         Brass
          The tubes are 1 in. OD, the fins are 2 in.  high, 0.038 in. thick, and   AI   120  0.535 0.86  86.1 426
          number 72/ft. The total tube length will be found with fins of  steel,
          brass, or aluminum:
             LMTD = (60 - 50)/1n(60/50) = 54.8,
                u5 = 61/20 + 1/200)-l= 18.18.
             Fin surface:

             A, = 72(2)(~/4)[(2.25'-  %)/I441 = 3.191 sqft/ft.
             Uncovered tube surface:

             A,  = (n/12)[1-  72(0.038/12)] ~0.2021 sqft/ft,
             A,/Ab  = 3.1'91/0.2021 = 15.79,
             y,  = half-fin thickness = 0.038/2(12) = 0.00158 ft.
             Abscissa of .the chart:

             x = (re - r,).dm= [(2.25 - 1)/24]~20/0.00158k
              = 5.86/<i,
             re/rb = 2.25,
             A5  = Q/ubaa(I f VAe/Ab)
                                  +
               = 1.25(1~16)/a8.18(54.8)(1 15.79~) sq ft.









             EXAMPLE 8.7
             Pressure Drop on the Tube  Side of  a Vertical Thermosiphon
             Reboiler
          Liquid with the properties of water at 5 atm and 307°F is reboiled at
          a  feed  rate  of  2800 Ib/(hr)(tube)  with  30 wt % vaporization.  The
          tubes are 0.1 ft ID and 12 ft long. The pressure drop will be figured
          at  an  average  vaporization  of  15%.  me Lockhart-Martinelli,
          method will be used, following Example 6.14, and the formulas of
          Tables 6.1 and 6.8:

                                 Liquid    Vapor
                  m (Ibihr)    2380        420
                  p (IbJft hr)   0.45       0.036
                  p (Ibl'cuft)   57.0       0.172
                  Re          67340      148544              Average density in reboiler tubes is
                  f              0.0220     0.0203
                  AP/b (psi/R)   0.00295    0.0281                        2800     = 1.13 lb/cuft.
             X2 = 0.0029.5/0.0281= 0.1051,                      pm = 2380/57 + 420/0.172
              c = 20,                                           Required height of liquid in tower above bottom of  tube sheet
             4:  = 1 f 20/X f 1/X2 = 72.21,
             (hP/L) two phase = 72.21(0.00295) = 0.2130,        pLh = 2.56(144) + 1.13(12),
             AP = 0.2130(12) = 2.56 psi,  5.90 ft water.          h = 382.2/57 = 6.7 ft.