Page 92 - Chemical process engineering design and economics
P. 92

Production and Capital Cost Estimation                          77

            Air  Coolers

            Correct for size.
                      (   145     r- 8

            CpB2i=137  |  ——— |  =$7,342
                      I  1   >l

                Correct for inflation  from mid-1987 to mid-1998. Use the cost index for heat
            exchangers.
                       382.8
            CPB i = 7,342  ———  =$8,739
                       321.6
                Correct  for  temperature  (fj  =1.1),  pressure  (f p  =  1.0),  and  materials-of-
            construction  (fM =  1.0).  There  is no  information  on  a correction factor  for design.
            Usef D =1.0.

            C PAi = 1.1 (1.0)  (1.0)  (1.0)  (8,739) = $9,613

                 Calculate the installation factor.

            f n  = (2.5)  (1.34) (1.18) = 3.953

            Dowtherm Pump

            Correct for size.
                       (   7.5 r-  42

            C PB2i = 9,000  | —— |  = $5,961
                       I  20.0  >/

                Correct  for inflation  from  January  1990  to mid-1998. Use  the  cost index for
            pumps.

                       648.5
            C PBi = 5,961  ——— =$7,844
                       492.8

            C PAi = 1.1 (1.0)  (1.0)  (1.0)  (7844) = $8,628

            f, i = 2.8(1.34) (1.18) = 4.427




         Copyright © 2003 by Taylor & Francis Group LLC