Page 125 - Control Theory in Biomedical Engineering
P. 125

Genetic fuzzy logic based system for arrhythmia classification  111



                        1040

                        1020

                        1000
                       Voltage(mV)  980



                         960


                         940

                         920
                               7200  7400  7600  7800  8000  8200  8400  8600
                                              Samples
              Fig. 5 Noisy signal ECG with baseline shift.


                        120

                        100
                         80

                         60
                       Voltage(mV)  40


                         20
                          0

                        –20
                        –40
                            7200  7400  7600  7800  8000  8200  8400  8600
                                              Samples
              Fig. 6 Noisy ECG signal without baseline shift.



              2.1.2 ECG feature extraction
              After eliminating the baseline wander, the algorithm Wavedet (Martı ´nez
              et al., 2004), developed in the toolbox ECG kit and carried out by Demski
              and Llamedo (2016), is applied to extract the morphological features. This
              algorithm has been applied for the detection of the ECG signal wave peaks