Page 542 - Fair, Geyer, and Okun's Water and wastewater engineering : water supply and wastewater removal
P. 542

JWCL344_ch14_500-554.qxd  8/7/10  8:56 PM  Page 500






                    Chapter 14










                                         Design of Sewer Systems





                    14.1  DRAINAGE OF BUILDINGS
                                         The water distributed to basins, sinks, tubs, bowls, and other fixtures in dwellings and
                                         other buildings, and to tanks and other equipment in industrial establishments, is col-
                                         lected as spent water by the drainage system of the building and run to waste (Fig. 14.1).
                                         Plumbing fixtures are arranged singly or in batteries. They empty into substantially
                                         horizontal branches or drains that must not flow full or under pressure if tributary fix-
                                          tures are to discharge freely and their protecting traps are not to become unsealed. The

                                                    Roof drain
                                             Roof
                                                                                         Either
                                                                          Connect to  arrangement
                                                              Stack vent
                                                                          stack vent
                                                       Leader    Loop vent

                                         Third floor
                                                                        Horizontal branch
                                                                                                    Indirect waste
                                                                Soil       Branch vent
                                                                vent                  Vent stacks
                                                                        Back vent
                                                                         Wet vent
                                        Second floor
                                                                   Relief vent
                                                                      Circuit vent
                                                                   Fixture  Side  Group  Either
                                                                    drain  vent  vent  arrangement
                                          First floor
                                                                                       Branch vent
                                                         Yoke vent
                                                                           Dry vent
                                        Building wall
                                                        Soil stack                     Continuous
                                                                                       waste vent     Dual (unit)
                                         Basement                                       Check           vent
                                                         Primary
                                               5 ft      branch            Cleanout      Discharge
                                                                                    Valve
                                     Building sewer  Building drain                       Sump
                                                                                         Floor drain


                                                                                           Building subdrain
                                     Figure 14.1 Building Drainage System. Conversion factor: 1 ft   0.3048 m.



                    500
   537   538   539   540   541   542   543   544   545   546   547