Page 64 - Subyek Teknik Mesin - Forsthoffers Best Practice Handbook for Rotating Machinery by William E Forsthoffer
P. 64

Be st Practice 2 .4           Pump Best Practices
       Integral gear centrifugal                              This pump design is commonly used when flow and head
                                                            requirements make it necessary to yield low values of NPSH
       This type of pump is used for low flow applications requiring  required. When designing piping systems for this type of pump,
       high head. Refer to Figure 2.4.4. The pump case design is  care must be taken to ensure equal flow distribution to each end
       similar to the inline, but incorporates pump bearings and an  of the impeller to prevent cavitation and vibration.
       integral gear to increase impeller speeds over 30,000 RPM.
                                                            Multistage horizontal split
       Single stage double flow between bearing
                                                            When the hydraulic limits of a single stage pump are exceeded,
       As the name implies, double suction impellers are mounted on  it is common practice to use a multistage pump, shown in
       between-bearing rotors, as shown in Figure 2.4.5.    Figure 2.4.6.










































       Fig 2.4.5   Single stage double flow between bearing (Courtesy of Union Pump Co.)






















       Fig 2.4.6   Multistage centrifugal pump (Courtesy of Union Pump Co.)

           38