Page 164 - Fundamentals of Magnetic Thermonuclear Reactor Design
P. 164

Superconducting Magnet Systems  Chapter | 5    145
























             FIGURE 5.21  TFMC design features (Copyright ITER Organization, 2017).




               TABLE 5.9 ITER TFC and TFMC Design Parameters

               Parameters                      TFC            TFMC
               Overall dimension (m)           14.7 × 8.5 × 1.4  3.8 × 2.7 × 0.77
               Mass (t)                        340            40
               Coil case thickness (mm)        75–240         70–80
               Total number of turns           134            98
               Number of DP modules            7              5
               Thickness of coil ground electrical   8        8
               insulation (mm)
               Thickness of electrical insulation between   5  4
               DPs (mm)
               Thickness of DP ground electrical   1.0        1.4
               insulation (mm)
               Thickness of electrical insulation between   1.25–2.0  2.5
               turns (mm)
               Conductor outer diameter (mm)   43.4           40.7
               Max. magnetic field (T)         11.5           8.8
               Max. magnetic field as a sum of TFC and   11.5  9.77
               LCT magnet operation (T)
               Max. operating current (kA)     68.0           80.0
   159   160   161   162   163   164   165   166   167   168   169