148     Fundamentals of Magnetic Thermonuclear Reactor Design



















































            FIGURE 5.24  Conductor operating current and relative deformation plots for the TFC and
            the TFCI coil.


               A PFCI with NbTi CIC SC was designed to operate at a current of 52 kA in
            a magnetic field of 6.4 T (Fig. 5.26). The NbTi strands and the cable of the PFCI
            were fabricated in the Russian Federation.
               The cable jacketing into a stainless-steel square tube was performed in the
            EU, as well as the manufacture of the mock-up of a low-resistance electrical
            joint between SC lengths, whose design verification was one of the objectives
            of the testing [12]. Joints like this are supposed to be used for all ITER NbTi
            conductor connections.