56      Gas Wettability of Reservoir Rock Surfaces with Porous Media








                                                            Microsyringe






                                                            Water or oil
                                                            Gas bubble


          FIGURE 2.20
          Schematic diagram of bubble capture method.




























          FIGURE 2.21
          Screenshot of five points fitting model measuring θ gas (125.16 degrees).

                            temperature. The different concentrations of Zonyl8740 water solution are
                            imbibed into the cleaned glass capillary and set aside for 4 hours before it is
                            sealed and dried in air at room temperature.
                            In the liquid phase, the bubble capture method is adopted for measuring gas
                            contact angle, and the size of bubble is 5 μL. The experimental measuring
                            interface is displayed in Fig. 2.20. The measurement mode of contact angle is
                            five points fitting model (see Fig. 2.21). The aim is to choose two points on