Page 405 - Handbook of Biomechatronics
P. 405

Current Advances in the Design of Retinal and Cortical Visual Prostheses  399


              Pezaris, J.S., Eskandar, E.N., 2009. Getting signals into the brain: visual prosthetics through
                 thalamic microstimulation. Neurosurg. Focus. 27, E6.
              Pezaris, J.S., Reid, R.C., 2007. Demonstration of artificial visual percepts generated through
                 thalamic microstimulation. Proc. Natl. Acad. Sci. 104, 7670–7675.
              Pezaris, J.S., Reid, R.C., 2009. Simulations of electrode placement for a thalamic visual
                 prosthesis. IEEE Trans. Biomed. Eng. 56, 172–178.
              Polikov, V.S., Tresco, P.A., Reichert, W.M., 2005. Response of brain tissue to chronically
                 implanted neural electrodes. J. Neurosci. Methods 148, 1–18.
              RamRakhyani, A.K., Mirabbasi, S., Chiao, M., 2011. Design and optimization of resonance-
                 based efficient wireless power delivery systems for biomedical implants. IEEE Trans.
                 Biomed. Circ. Syst. 5, 48–63.
              Rasouli, M., Phee, L.S.J., 2010. Energy sources and their development for application in
                 medical devices. Expert Rev. Med. Device 7, 693–709.
              Raz-Prag, D., Weinberger, D., Gefen, R.A., 2014. Implantation procedure for retinal
                 prosthesis: adaptation of extracapsular cataract procedure. Investig. Ophthalmol. Vis.
                 Sci. 55, 1809.
              Rizzo, J.F., 2011. Update on retinal prosthetic research: the Boston retinal implant project.
                 J. Neuroophthalmol. 31, 160–168.
              Rizzo III, J.F., Ayton, L.N., 2014. Psychophysical testing of visual prosthetic devices: a call to
                 establish a multi-national joint task force. J. Neural Eng. 11, 020301.
              Rizzo, J.F., Wyatt, J., Loewenstein, J., Kelly, S., Shire, D., 2003. Perceptual efficacy of elec-
                 trical stimulation of human retina with a microelectrode array during short-term surgical
                 trials. Investig. Ophthalmol. Vis. Sci. 44, 5362–5369.
              Roessler, G., Laube, T., Brockmann, C., Kirschkamp, T., Mazinani, B., Goertz, M.,
                 Koch, C., Krisch, I., Sellhaus, B., Trieu, H.K., Weis, J., Bornfeld, N., Rothgen, H.,
                 Messner, A., Mokwa, W., Walter, P., 2009. Implantation and explantation of a wireless
                 epiretinal retina implant device: observations during the EPIRET3 prospective clinical
                 trial. Investig. Ophthalmol. Vis. Sci. 50, 3003–3008.
              Romero-Ortega, M., Kanneganti, A., Bendale, G., Seifert, J., Bredeson, S., Troyk, P.,
                 Deku, F., Cogan, S., 2015. In: Chronic and low charge injection wireless intraneural
                 stimulation in vivo.2015 37th Annual International Conference of the IEEE Engineering
                 in Medicine and Biology Society (EMBC), pp. 1013–1016.
              Sabbah, N., Authi , C.N., Sanda, N., Mohand-Said, S., Sahel, J.-A., Safran, A.B., 2014.
                           e
                 Importance of eye position on spatial localization in blind subjects wearing an argus ii
                 retinal prosthesiseye position, localization, and retinal prosthesis. Investig. Ophthalmol.
                 Vis. Sci. 55, 8259–8266.
              Sahel, J., Mohand-Said, S., Stanga, P., Caspi, A., Greenberg, R., 2013. Acuboost™: enhanc-
                 ing the maximum acuity of the Argus II retinal prosthesis system. Investig. Ophthalmol.
                 Vis. Sci. 54, 1389.
              Sailer, H., Shinoda, K., Blatsios, G., Kohler, K., Bondzio, L., Zrenner, E., Gekeler, F., 2007.
                 Investigation of thermal effects of infrared lasers on the rabbit retina: a study in the course
                 of development of an active subretinal prosthesis. Graefes Arch. Clin. Exp. Ophthalmol.
                 245, 1169–1178.
              Sakaguchi, H., Fujikado, T., Fang, X., Kanda, H., Osanai, M., Nakauchi, K., Ikuno, Y.,
                 Kamei, M., Yagi, T., Nishimura, S., 2004a. Transretinal electrical stimulation with a
                 suprachoroidal multichannel electrode in rabbit eyes. Jpn. J. Ophthalmol. 48, 256–261.
              Sakaguchi, H., Fujikado, T., Kanda, H., Osanai, M., Fang, X., Nakauchi, K., Ikuno, Y.,
                 Kamei, M., Ohji, M., Yagi, T., 2004b. Electrical stimulation with a needle-type
                 electrode inserted into the optic nerve in rabbit eyes. Jpn. J. Ophthalmol. 48, 552–557.
              Sakaguchi, H., Kamei, M., Fujikado, T., Yonezawa, E., Ozawa, M., Cecilia-Gonzalez, C.,
                 Ustariz-Gonzalez, O., Quiroz-Mercado, H., Tano, Y., 2009. Artificial vision by direct
                 optic nerve electrode (AV-DONE) implantation in a blind patient with retinitis
                 pigmentosa. J. Artif. Organs 12, 206–209.
   400   401   402   403   404   405   406   407   408   409   410