Page 138 - Handbook of Civil Engineering Calculations, Second Edition
P. 138

STRUCTURAL STEEL DESIGN               1.121

                              3. Select the lesser value of the ultimate load
                              The correct result is the lesser of these alternative values, or P u   52.8 kips (234.85 kN).
                              At this load, plastic hinges exist at B and C but not at D.
                              4. For the mechanism method, assume a plastic-hinge location
                              It will be assumed that plastic hinges are located at B and C (Fig. 26). Evaluate P u . Thus,
                              	 C   14	 A /16;  	 B   30	 A /16;
                              14	 A ;  W E   P u    14P u 	 A ;  W I
                              M p (	 B +  	 C )    2.75M p 	 A ; 14P u 	 A
                              2.75M p 	 A ; P u   52.8 kips (234.85 kN).
                              5. Assume a plastic hinge
                              at another location
                              Select  C and  D for the new location.
                              Repeat the above procedure. The result
                              will be identical with that in step 2.
                                                              FIGURE 26

                              SELECTION OF SIZES FOR
                              A CONTINUOUS BEAM

                              Using a load factor of 1.70, design the member to carry the working loads (with beam weight
                              included) shown in Fig. 27a. The maximum length that can be transported is 60 ft (18.3 m).
                              Calculation Procedure:

                              1. Determine the ultimate loads to be supported
                              Since the member must be spliced, it will be economical to adopt the following design:
                              a. Use the particular beam size required for each portion, considering that the two por-
                                tions will fail simultaneously at ultimate load. Therefore, three plastic hinges will exist
                                at failure—one at the interior support and one in the interior of each span.
                              b. Extend one beam beyond the interior support, splicing the member at the point of con-
                                traflexure in the adjacent span. Since the maximum simple-span moment is greater for
                                AB than for BC, it is logical to assume that for economy the left beam rather than the
                                right one should overhang the support.
                                Multiply the working loads by the load factor to obtain the ultimate loads to be sup-
                              ported. Thus, w   1.2 kips/lin ft (17.51 kN/m); w u   1.70(1.2)   2.04 kips/lin ft (29.77
                              kN/m); P   10 kips (44.5 kN); P u   1.70(10)   17 kips (75.6 kN).
                              2. Construct the ultimate-load and corresponding
                              bending-moment diagram for each span
                              Set the maximum positive moment M D in span AB and the negative moment at B equal to
                              each other in absolute value.
                              3. Evaluate the maximum positive moment in the left span
                                                                       2
                              Thus, R A   45.9 – M B /40; x   R A /2.04; M D   /2R A x   R A /4.08   M B . Substitute the val-
                                                                1
                              ue of R A and solve. Thus, M D   342 ft·kips (463.8 kN·m).
                                An indirect but less cumbersome method consists of assigning a series of trial values
                              to M B and calculating the corresponding value of M D , continuing the process until the re-
                              quired equality is obtained.
                              4. Select a section to resist the plastic moment
                                                            3
                                                                     3
                              Thus, Z   M p /f y   342(12)136   114 in (1868.5 cm ). Referring to the AISC Manual,
                                                       3
                                                                 3
                              use a W21   55 with Z   125.4 in (2055.31 cm ).