FIGURE  4  Logarithmic  mean  temperature  for  a  variety  of  heat-
                     transfer applications.



               SELECTING AND SIZING HEAT EXCHANGERS BASED ON

               FOULING FACTORS



               A heat exchanger having an overall coefficient of heat transfer of U = 100
                                                   2
                       2
               Btu/(ft  · h · °F) [567.8 W/(m  · °C)] is used to cool lean oil. What effect will
               the tube fouling have on the value of U for this exchanger?


               Calculation Procedure:


               1. Determine the heat exchange fouling factor
               Use  Table  2  to  determine  the  fouling  factor  for  this  exchanger.  Thus,  the
               fouling factor for lean oil = 0.0020.



                          TABLE 2 Heat-Exchanger Fouling Factors              *