Welded Joint Design and Production

                    252   Chapter Three

                    where the same width of material is joined, weld tabs that extend
                    beyond the width of the joint would not be expected to carry signifi-
                    cant stress levels, making weld tab removal less important. Tab
                    removal from continuity plate welds is probably not justified.
                      The presence of weld tabs left-in-place is probably most significant for
                    beam-to-column connections where columns are box shapes. The natural
                    stress distribution under these conditions causes the ends of the groove
                    weld between the beam and column to be loaded to the greatest level,
                    the same region as would contain the weld tab. Just the opposite situation
                    exists when columns are composed of l-shaped members. The center of
                    the weld is loaded most severely, and the areas in which the weld tabs
                    would be located have the lowest stress level. For welds subject to high
                    levels of stress, however, weld tab removal is recommended.

                      Welds in combination with bolts. Welds provide a continuous metal-
                    lurgical path that relies upon the internal metallurgical structure of
                    the fused metal to provide continuity and strength. Mechanical fasten-
                    ers such as rivets and bolts rely on friction, shear of the fastening ele-
                    ment, or bearing of the joint material to provide for transfer of loads
                    between members. When welds are combined with bolts, caution must
                    be exercised in assigning load-carrying capacity to each joining method.
                      Traditionally it has been assumed that welds that are used in con-
                    junction with bolts should be designed to carry the full load, assuming
                    that the mechanical fasteners have no load-carrying capacity until the
                    weld fails. With the development of high-strength fasteners, it has been
                    assumed that loads can be shared equally between welds and fasten-
                    ers. This has led to connection details which employ both joining sys-
                    tems. In particular, the welded flange, bolted web detail used for many
                    beam-to-column connections in special moment-resisting frames
                    (SMRF) assumes that the bolted web is equally able to share loads with
                    the welded flanges. While most analysis suggests that vertical loads
                    are transferred through the shear tab connection (bolted) and moments
                    are transferred through the flanges (welded), the web does have some
                    moment capacity. Depending on the particular rolled shape involved,
                    the moment capacity of the web can be significant. Testing of speci-
                    mens with the welded web detail, as compared to the bolted web detail,
                    generally has yielded improved performance results. This has drawn
                    into question the adequacy of the assumption of high-strength bolts
                    sharing loads with welds when subject to inelastic loading. Research
                    performed after the Northridge earthquake provides further evidence
                    that the previously accepted assumptions may have been inadequate.
                    This is not to suggest that bolted connections cannot be used in con-
                    junction with welded connections. However, previous design rules
                    regarding the capacity of bolted connections need to be reexamined.
                    This may necessitate additional fasteners or larger sizes of shear tabs