Page 101 - Industrial Process Plant Construction Estimating and Man Hour Analysis
P. 101

74  Industrial process plant construction estimating and man-hour analysis


            4.4.2 Erect headers and panels, weld water wall tubes, burner, soot
            blower, superheater sheet 2


                                              Historical         Estimate
            Description                 MH     Qty     Unit  Qty  Unit   BM
            Erect headers and wall panels, fit and                       0
              weld wall panels
            Scaffolding and rigging     136.00  1.0    Boiler  0  Boiler  0
            Erect right side wall panels—water  2.50  120.0  Ton  0  Ton  0
              wall
            Fit and weld filler bar at tube welds  1.00  468.0  Space  0  Space  0
            Fit and weld filler joining membrane  0.60  160.0  LF  0  LF  0
              panels
            Erect left side wall panels—water wall  2.50  120.0  Ton  0  Ton  0
            Fit and weld filler bar at tube welds  1.00  468.0  Space  0  Space  0
            Fit and weld filler joining membrane  0.60  160.0  LF  0  LF  0
              panels
            Erect front wall panels—water wall  2.50  120.0  Ton  0  Ton  0
            Fit and weld filler bar at tube welds  1.00  432.0  Space  0  Space  0
            Fit and weld filler joining membrane  0.60  156.0  LF  0  LF  0
              panels
            Erect rear wall panels—water wall  2.50  120.0  Ton  0  Ton  0
            Fit and weld filler bar at tube welds  1.00  432.0  Space  0  Space  0
            Fit and weld filler joining membrane  0.60  156.0  LF  0  LF  0
              panels
            Erect roof panels—water wall  2.50  90.0   Ton   0    Ton    0
            Fit and weld filler bar at tube welds  1.00  588.0  Space  0  Space  0
            Fit and weld filler joining membrane  0.60  173.0  LF  0  LF  0
              panels
            Fit and weld water wall tubes  4.20  1645.8  EA  0    EA     0
            Erect, fit, and weld primary/                                0
              secondary headers
            Primary superheater headers/coils  4.20  96.6  Ton  0  Ton   0
            10.75 Diameter inlet header  4.00  2.1     Ton   0    Ton    0
                00
            20 Outlet header            4.00   5.0     Ton   0    Ton    0
              00
            Weld superheater tubes; 1.772 OD  3.70  292.0  EA  0  EA     0
                                  00
            Burner System                                                0
            Burner and wind box         59.40  4.7     Ton   0    Ton    0
            Fan with drive              0.00   1.8     Ton   0    Ton    0
            Silencer                    0.00   1.0     EA    0    EA     0
            Soot blowers                                                 0
            Soot blower
            Install rotary and retractable soot
              blowers
            Superheater—soot blower with pipe,  64.00  12.0  EA  0  EA   0
              valve, fitting
            Economizer—soot blower with pipe,  64.00  4.0  EA  0  EA     0
              valve, fitting
            Generating bank—soot blower with  64.00  4.0  EA  0   EA     0
              PVF
   96   97   98   99   100   101   102   103   104   105   106