Page 220 - Industrial Process Plant Construction Estimating and Man Hour Analysis
P. 220
196 Industrial Process Plant Construction Estimating and Man-Hour Analysis
9.15 Receiver heat shields set estimate data
9.15.1 Assemble and erect heat shields set sheet 1
Description MH Unit
Heat shields sets
Structural—connect to heat shield 2 EA
Upper heat shield sets 40 EA
Structural—connect to heat shield 4 EA
Lower heat shield sets 40 EA
Corrugated steel panel 4 EA
Door 10 EA
Bolt connection 1 EA
Joint between heat shields
Upper heat shield support rings 4 EA
W16x31, W6x12, C15x33.9 4 EA
W16x31, W6x12, C15x33.9 4 EA
W16x31, W6x12, C15x33.9 4 EA
W16x31, W6x12, C15x33.9 4 EA
Field seams 2 EA
Bolt connection 1 EA
9.16 Receiver heat shields set installation estimate
9.16.1 Assemble and erect heat shields set sheet 1
Estimate
Description MH Qty Unit Qty Unit IW
Heat shield sets 0
Structural—connect to heat shield 2 336 EA 0 EA 0
Upper heat shield sets 40 14 EA 0 EA 0
Structural—connect to heat shield 4 24 EA 0 EA 0
Lower heat shield sets 40 14 EA 0 EA 0
Corrugated steel panel 4 14 EA 0 EA 0
Door 10 1 EA 0 EA 0
Bolt connection 1 756 EA 0 EA 0
Joint between heat shields 0
Upper heat shield support rings 4 28 EA 0 EA 0
W16x31, W6x12, C15x33.9 4 30 EA 0 EA 0
W16x31, W6x12, C15x33.9 4 30 EA 0 EA 0
W16x31, W6x12, C15x33.9 4 30 EA 0 EA 0
W16x31, W6x12, C15x33.9 4 30 EA 0 EA 0
Field seams 2 140 EA 0 EA 0
Bolt connection 1 240 EA 0 EA 0