Page 159 - Instrumentation Reference Book 3E
P. 159

Further reading  143

                                                      for pressure and temperature, continuous samples,
                           Transducer
                                                      and sample and hold. Up to 100 samples per second
                  PreSSWe            Temperature      can be  obtained with special burst sampling com-
                   signal             signal          mands.  The  internal  serial  bus  communicates
                                                      with the outside world by means of a digital field-
                                                      bus  connection, such  as  Profibus or  Foundation
                         1"T'l:" frequency            Fieldbus.
                              ,            J          9.4  References
               EPROM
                          Microprocessor
                                                      An  Introduction  to  Process  Control,  Pub.  105B, The
                           A     I                      Foxboro Company (1986)
                                                      Busse, D. W.. "Quartz transducers for precision under
                                            RS485       pressure,"  Meclianical Engineering, 109. No. 5  (May
                                                        1987)
                                                      Gillum. D. R., Industrial Pressure Measurement, Instru-
                                                        ment Society of America. NC, USA (1982)
                                         RS485  RS485   Hewson, J. E., Process Instruinentation Manifolds: their
                                          IN   OUT
                                                        Selection  and  Use, Instrument  Society of  America,
                RS232 IN                RS232 OUT       NC. USA (1981)
                            interface
                                                      Lyons, J. L., The Designer's Handbook of  PI-essure-Sen-
             Figure 9.46  Digital interface board. Courtesy,   sing  Devices,  Van  Nostrand  Reinhold,  New  York
             Paroscientific Inc.                        (1980)
                                                      Neubert, H. K. P.: Instruinent Transducers: an Introduc-
             time,  baud  rate,  pressure  adders,  and  pressure   tion  to  their  Perforinance  and  Design, Clarendon
             multipliers.  Resolution  is  programmable  from   Press, Oxford (1975)
             0.05 to  100 parts per million; depending  on sys-
             tem requirements. Baud rates up to 115.2K baud   9.5  Further reading
             can  be  selected. Pressure  data  are  available  in
             eight different or user-defined engineering units.   British Geotechnical Society, Pressuremeters, American
             The command set includes single sample requests   Society of Civil Engineers, New York (1990)