Workflow Automation and Intelligent Control                  187


              intake pressure (PIP), motor temperature (MT), and many other operating
              data. These components are shown in Fig. 5.20.
                 Input: WHP, THP, water, oil, and gas meters. Frequency, amperage,
                 voltage, and choke size are the traditional surface data observed in the
                 control panel. PIP, PDP, and MT are the down-hole data read directly






















































              Fig. 5.20 ESP diagram showing the most important components useful for monitoring
              in real time.