BUTTOn CELL BATTErIES: SILVEr OxIDE–ZInC AnD ZInC-AIr SYSTEmS        13.35

                                                                 620 ohm 16 h/day
                                                          95% confidence interval for the mean
                                          110%




                                         Relative capacity  100%                                100%





                                           90%




                                           80%
                                     Test humidity  20% 50% 80%  20% 50% 80%     20% 50% 80%
                                         design        A               B               C
                                     FiGURE 13.35  The initial 20 and 80% relative humidity capacity performance as a percentage of each
                                     design’s 50% relative humidity performance on the 620 ohm, 16 h/day test at 20°C.


                                                           620 ohm 16 h/day percent retention
                                                after 7 days 20°C open stand 95% confidence interval for the mean
                                      100%


                                     Relative capacity retention  80%
                                       90%





                                       70%



                                       60%

                                    Humidity  20%  50%   80%     20%   50%  80%     20%   50%  80%
                                     design         A                   B                  C
                                    FiGURE 13.36  The percentage retention of the initial capacity on the 620 ohm, 16 h/day test after 7 days
                                    open stand in 20, 50, and 80% relative humidity open stand at 20°C.


                                was changed to 16 to 18 days, a significant loss to performance occurred at 20% relative humidity.
                                Design B with the middle limiting current range and higher internal battery relative humidity had a
                                15% performance loss in the low-humidity test environment.
                                   Figure 13.36 summarizes the percent of the initial performance the various designs obtained on
                                the moderate drain 620 ohm test after 7 days open stand. For instance, a sample of design C was left