434    CHAPTER 2  Preparation and Use of Performance Standards





                           INSTALLATION:  PERFORMANCE STANDARD: INTERNAL COMMUNICATIONS (cont.)

                           Functions      Element                          Assurance
                           3  To provide essential   a) The central control systems for the  communications are all   By Design
                              control equipment for   located within the TR
                              the communications
                              systems within a   During ESD situations, non-essential equipment and supplies are
                              designated safe area   disconnected for safety reasons.  Equipment that remains
                              such that   operational includes: PA, PABX, hand portables, INMARSAT,
                              communications may   VHF radio, repeater and status systems, and navigation
                              be maintained in the   equipment.
                              event of hazard.
                           4  To provide a redundant  a) A fibre optic link with redundant fibres is provided between   Referencemaintenance
                              link between the   these installations to provide as a minimum data and status of   procedure XXXXX.
                              Installation and other   the safety systems.
                              installations in the field
                           5  To provide visual   a) Visual warning in the form of high intensity amber coloured
                              announcement of   flashing beacons are provided to supplement audible alarm   Reference maintenance
                              emergency in high   signals and emergency announcements in all areas, where   procedure XXXXX.
                              noise areas   ambient noise is 85 dBA or greater.
                           6   To provide safe   An UHF (FM) radio repeater system is installed to enhance full   Reference maintenance
                               mobile     duplex radio communications between personnel using hand   procedure XXXXX.
                               communications   portables. In the event of failure the hand portables are equipped
                               between control   with simplex channels to allow communications, hand portable to
                               rooms and all areas  hand portable, between personnel on the facility.
                                           a)  Intrinsically safe multi-channel mobile FM VHF & UHF
                                             hand portable radios with mains, single and multi,
                                             chargers are provided for use by production,
                                             maintenance, crane operating and safety personnel.
                                          Private channels are used for communications with the shuttle
                                          tanker, supply vessels, crane cabs and hand portables.  Each
                                          crane is equipped for communication with supply vessels.
                           7   To provide safe   A distributed emergency intercom system, fully certified for use   Reference maintenance
                               communications   in hazardous areas, provides voice communication between   procedure XXXXX.
                               between control   control centres, muster areas and lifeboat locations.
                               rooms and muster
                               areas.
                           8   To provide a call   a)  A radio paging system with facility for sending verbal   Reference maintenance
                               system to essential   messages, which may be accessed from the installation   procedure XXXXX.
                               personnel in the   telephone systems, enables key personnel to be paged.
                               event of an incident
                                          b) Telephones shall be clearly marked and sign-posted.
                           9   To provide visual   Closed circuit television (CCTV) is installed at various   Reference maintenance
                               monitoring for   strategic positions on the Installation to allow control room   procedure XXXXX.
                               Control Room   operators to watch high-risk areas of the installation.
                               Personnel.  High risk areas of the FPSO covered by CCTV include CCTV
                                           viewing of cargo offloading areas, flare and PAUs,and also
                                           helideck.
                           10  Provide fail-safe   a) A telemetry system is installed on the FPSO to facilitate   Reference maintenance
                              operations and   supervisory and control of the off-loading system.  procedure XXXXX.
                              shutdown of cargo in   b) The CCR also provides voice communication between the
                              the event of a problem   FPSO control room, Machinery, and the shuttle tanker loading
                              on the shuttle tanker.  control point (aft).
                           11  Prevent toxic spill to   Chemicals and fuel to be provided with secondary containment   -
                              Environment   where necessary [No inventory related to internal coms]
                             Reliability &                                      Reference
                             Availability
                           The Internal coms system is based on a duplex system, operating in parallel.  Safety Case
                           The system monitors its own status and its power supplies and alarms all faults.  Sect. XXXXX
                           The specified availability of the Internal system is as follows:
                            ∑  99.1%
                           The availability figure specified is the equipment availability of communication to each field  Reliability Report
                           instrument.                                        Doc No. XXXX
                           FIGURE 9.2.1, cont’d