Preparation and Use of Performance Standards  435





                          INSTALLATION:     PERFORMANCE STANDARD:  INTERNAL COMMUNICATIONS (cont.)
                     Survivability             Requirement               Assurance
                  Explosion       Individual field instruments are not expected to survey a local   Design drawings and
                                  explosion                            inspection.
                  Fire            Cabling Circuits with safety functions such as PA / alarm systems   Verified through
                                  have fire resistant characteristics to IEC 331. Cable routing is   inspection and testing.
                                  designed to minimise the probability of damage from fire. Duplicate   Design drawings and
                                  redundant circuits or supplies provide compliance with the   inspection.
                                  requirements of protection of safety or essential systems and follow
                                  separated as far as practicable.
                  Pool/jet fire   Damage to individual communications units or cabling will alarm   Verified through
                                  through the line monitoring/self-checking system.  inspection and testing.
                                                                       Design drawings and
                                                                       inspection.
                                                                       See standard XXXXX
                  Environmental                Requirement               Reference
                  Prevent toxic spill to   Chemicals and fuel to be provided with secondary containment where   -
                  Environment     necessary [No significant inventory related to internal coms systems]
                  Interacting systems      Dependence/Interaction        Reference
                  UPS Systems     Dependent on UPS power supplies      Verified through
                  F&G Systems     PA system broadcasts vessel-wide alarms as required  inspection and testing.
                                                                       Design drawings and
                                                                       inspection.
                                                                       See standard XXXXX
                  FIGURE 9.2.1, cont’d