Page 84 - Structural Steel Designers Handbook AISC, AASHTO, AISI, ASTM, and ASCE-07 Design Standards
P. 84

Brockenbrough_Ch03.qxd  9/29/05  5:05 PM  Page 3.16



                                                        CONNECTIONS


                   3.16  CHAPTER THREE




















                                         FIGURE 3.10  Typical welded splice of columns when depth D U of the upper col-
                                         umn is nominally 2 in less than depth D L of the lower column.

                   3.2.5 Bolt Installation: Snug-Tight versus Fully Tensioned

                               High-strength bolts (A325 and A490) can be installed either snug-tight or fully tensioned. Common
                               bolts (A307) can only be installed snug-tight. Snug-tight installation is achieved when all plies are
                               in contact. It can be attained by a few impacts of an impact wrench or the full effort of a person using
                               an ordinary spud wrench. Fully tensioned installation is achieved when the bolt is stressed in tension
                               to 70% of its tensile strength. The RCSC Specification requires fully tensioned installation for the
                               following conditions:
                               1. Joints in which fastener pretensioning is required in the specification or code that invokes the
                                 Specification
                               2. Joints that are subjected to significant load reversal
                               3. Joints that are subjected to fatigue load with no reversal of the loading direction
                               4. Joints with ASTM A325 or F1852 bolts that are subject to tensile fatigue
                               5. Joints with ASTM A490 bolts that are subject to tension or combined shear and tension, with or
                                 without fatigue




















                                             FIGURE 3.11  Typical bolted splice of columns when depth D U of the
                                             upper column is nominally 2 in less than depth D L of the lower column.



                           Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com)
                                      Copyright © 2004 The McGraw-Hill Companies. All rights reserved.
                                       Any use is subject to the Terms of Use as given at the website.
   79   80   81   82   83   84   85   86   87   88   89