Page 100 - Sustainability in the Process Industry Integration and Optimization
P. 100

P r o c e s s I n t e g r a t i o n f o r I m p r ov i n g E n e r g y E f f i c i e n c y   77


                        Once utility levels are chosen, the heat pump can be placed also
                     across a Utility Pinch (Figure 4.38). A special case of integration
                     involves the placement of refrigeration levels (Figure 4.39).
                     Refrigeration facilities are heat pumps whose main value is that their
                     cold end absorbs heat. Utilizing their hot ends for process heating
                     can save considerable amounts of hot utility, especially when
                     relatively low-temperature heating is needed.
                     Distillation Processes and Other Separations
                     The simplest distillation column includes one reboiler and one
                     condenser, and these components account for most of the column’s

                                 T*
                                                         HP


                                                 MP



                                               IP
                                           LP







                                      CW
                                                               ΔH
                     FIGURE 4.38  Heat-pump placement across the utility Pinch.


                                           T*






                                                 R cond  CW
                                     HEAT   0
                               W
                                    PUMP
                                               R 1

                                                     R 2
                                                                  ΔH

                     FIGURE 4.39  Refrigeration systems.
   95   96   97   98   99   100   101   102   103   104   105