Page 245 - Sustainability in the Process Industry Integration and Optimization
P. 245

222   Cha p te r  T e n


                                                                      CP [kW/°C]
                       40.0°          99.7°         190.0°   337.0°
                             C3                  E2     E1       H1       100
                              5970 kW
                       160.0°                              220.0°
                                              E4                 H2       160
                       60.0°       88.0°                   220.0°
                            C6             E5                    H3        50
                       45.0°     118.55°                   160.0°
                               C10    E7                         H4       190

                          100.0°                           247.0°  300.0°
                       C1                                       H8        100
                          35.0°                     14700 kW 5300 kW  164.0°
                       C2                                                  70
                          80.0°                 9030 kW            125.0°
                       C3                                                 175
                                 7875 kW
                          60.0°                                    170.0°
                       C4                                                  60
                                     6600 kW
                          140.0°                         188.0°    300.0°
                       C5                                        H9       200
                                             9600 kW           22400 kW
                     FIGURE 10.3  Calculated grid diagram for Problem 1.



                                               Load-shift path
                                                                     CP [kW/°C]
                        40.0°       T H12           T H11  337.0°
                              C3                 E2     E1      H1       100
                               Q C3
                        160.0°                             220.0°        160
                                              E4                H2
                                  88.0°
                        60.0°                              220.0°
                             C6            E5                   H3        50
                           1400 kW
                                 118.55°
                        45.0°                              160.0°        190
                               C10      E7                      H4
                                13984 kW
                           100.0°                           T      300.0°  100
                        C1                                  C11  H8
                                                      Q E1   Q H8
                           T   =35.0°°                        T C2,out =164.0°  70
                        C2  C2,in
                           80.0°                9030 kW            125.0°  175
                        C3
                           60.0°   7875 kW                         170.0°
                        C4                                                60
                                      6600 kW
                           140.0°                     188.0°       300.0°
                        C5                                      H9       200
                                            9600 kW         22400 kW
                     FIGURE 10.4  The load-shift path identifi ed for Problem 1.
   240   241   242   243   244   245   246   247   248   249   250