3-28   WATER AND WASTEWATER ENGINEERING

                            Standards Institute (ANSI) has provided the following guidance for the  Preferred Operating
                            Range  (POR) for vertical pumps (ANSI/HI 9.6.3-1997):
                                     For specific speeds less than 87, the bounded region is between 70 and 120 percent of the
                                 BEP flow rate.
                                    For higher specific speeds, the bounded region is between 80 and 115 percent of the BEP
                                 flow rate.

                               Specific speed  is defined as
                                                                       .
                                                                    nQ 0 5
                                                               n s    075                                (3-9)
                                                                       .
                                                                    H t
                            where     n       revolutions per minute
                                                 3
                                      Q       flow rate, m  /s
                                      H    t        total dynamic head, m
                                ANSI also established a wider region than the POR called the  Acceptable (or Allowable)
                            Operating Region  (AOR). It “is that range of flow recommended by the pump manufacturer over
                            which the service life of a pump is not seriously compromised. Minimum bearing life will be
                            reduced and noise, vibration, and component stresses will be increased when a pump is operated
                            outside its POR. As a result, service life within the AOR may be lower than within the POR.” The
                            pump may be operated in this region for short, infrequent periods without significant equipment
                            deterioration (Cooper and Tchobanoglous, 2006).

                              Example 3-6.   Using the pump head-discharge curve shown in  Figure 3-17  for the system head
                            curve shown in  Figure 3-16 , and data from Example 3-5, specify the following at the average
                            flow rate: (1) BEP, (2) number of stages, (3) efficiency at BEP, (4) the operating range of flow
                            rate, (5) motor power, (6) the depth of the wet well, and (7) the location of the pump intake.

                              Solution:
                                   a.  From  Figure 3-16 , the maximum total system head is 18.4 m at the average flow rate
                                            3
                                   of 6,000 m  /d. On  Figure 3-17,  the BEP is found at a flow rate of
                                                                     3
                                                              6 000 m /d        3
                                                               ,
                                                                           250 m /h
                                                                24 h/d
                                   and a head of 3 m/stage.
                                 b.  The number of stages required is
                                                              Total system head  18 4 .  m
                                                No of stages                            613.  or 7
                                                  .
                                                               Head per stagge    3
                                   This is less than the maximum number of stages allowed of 35 noted in the box in
                                     Figure 3-17 .
                                                          3
                                 c.  From  Figure 3-17  at 250 m  /h and 3 m head per stage, the efficiency is 78 percent for
                                   impeller  A.
                                 d.  From  Figure 3-17 , the rpm     1,750. The flow rate is

                                                                   3
                                                             250 m /h           3
                                                                         0 0694 m /s
                                                                         .
                                                              ,
                                                             3 600 s/h