Page 176 - Advances in Renewable Energies and Power Technologies
P. 176

3. Smart Maximum Power Point Tracker Under Partial Shading Conditions    149





































                  FIGURE 4.34
                  The relation between output power and terminal voltage for two series PV cells with
                  bypass diodes at different shading conditions.


                  generated power from PV system. Also, the lower the value of MML factor, the
                  higher the hot spot on the PV cell with lower solar radiation. If the whole PV cells
                  have the same radiation and the whole PV system works at its MPP and each cell
                  works at its own MPP, the MML factor will be 100%. The value of MML factor
                  can be obtained from the following equation:
                                     Maximum power of whole PVsystem
                              MML ¼                                   100       (4.30)
                                                N
                                                P
                                                  PmaxðiÞ
                                                i¼1
                  where, N is the total number of PV cells in PV system.
                     So depending on the PV system shown in Fig. 4.37, the MML factor can be ob-
                  tained as follows.
                     If the system operates at the MPP #1
                                               60
                                   MML ¼                100 ¼ 28:03%
                                           60 þ 90 þ 64
   171   172   173   174   175   176   177   178   179   180   181