Page 223 - Advances in Renewable Energies and Power Technologies
P. 223
196 CHAPTER 5 DMPPT PV System: Modeling and Control Techniques
FIGURE 5.16
Grid-connected photovoltaic (PV) system adopting boost-based lossless self-controlled
PV units: (A) HMPPTF technique, (B) HMPPTS technique.
Table 5.2 Modified P&O (MP&O) Parameters
Sampling interval of MP&O T a ¼ 1.5 ms
Amplitude of the perturbation of MP&O Dv pan ref ¼ 0.15 V
Guard level HMPPTS V out lim ¼ 53 V
Guard level HMPPTF V out lim ¼ 59 V