C h a p t e r   7


 220
              Submodes of IGC
          Modes (MD j ) and Submodes (SD j ) to be Considered
              Submodes of SCC
                  MRSCC    Wear    Fatigue    Pitting    Wastage    AkIGC    AcIGC    HPIGC    PbSCC    AkSCC    (  j = 13)  (  j = 12)  (  j = 11)  (  j = 10)  (  j = 9)  (  j = 8)  (  j = 7)  (  j = 6)  (  j = 5)  (  j = 4)  Abbreviations used are low potential (LP), high potential (HP), mid-range pH (MR), alkaline (AK), lea
                  AcSCC    (  j = 3)


                  HPSCC    (  j = 2)


                  LPSCC    (  j = 1)                                     Matrix for Organizing Mode-Location Cells


                   OD     x       x   x       x   x   x       x
                   ID  x      x           x               x



             Locations    for Analysis  LA i  Tubular expansion    (i = 1)  Tubular expansion    (i = 2)  Top of tube sheet    (i = 3)  Top of tube sheet    (i = 4)  Sludge    (i = 5)  Free span    (i = 6)  Free span    (i = 7)  Tube support    (hot leg) (i = 8)  Tube support    (cold leg) (i = 9)  U-Bend    (i = 10)  U-Bend A
   241   242   243   244   245   246   247   248   249   250   251