Page 255 - Failure Analysis Case Studies II
P. 255

240




                                  8



                    DEFLECTION










                                                   I                 I  .
                                                 2000              4000
                                               TIME TO FAILURE(DAYS)
                                Fig. 7. Time to fatigue failure versus spindle deflection.


            compressive stresses (by shot peening) have remained in HP heater water chambers after 5 years at
            270°C.
             Finally, it has been shown that thread re-profiling and shot peening can mitigate fatigue failure
            in valve spindles. Also regular checks of actuating system out-of-alignment should be carried out
            together with good insulation at key locations which should help minimise thermal distortions.


                                           REFERENCES

            1.  Amzallag, C. and  Maillard,  J.  L.,  9th Inter.  Conf.  Structural Mechanics in  Reactor  Technology,  Smirt,  Lausanne,
             Switzerland, Aug.  1987, Vol. F, pp.  173-180.
            2.  Gauchet, J. P., Reversat, C.,  Leguernic, Y.,  Lebrun, J. L., Castax, L. and Barrallier, L. K., EDF Feedback on French
             Feedwater Plants Repaired by Shot Peening, EPRI Inter. Conf. Welding & Repair Technology for Fossil Power Plants,
             March  1994, Williamsburg, Virginia, U.S.A.
   250   251   252   253   254   255   256   257   258   259   260