Lube, Seal and Control Oil System Best Practices  Best Practice 7 .15

                                                                                      Fig 7.15.10   Filter sizing nomograph
                                                                                      (Courtesy of Filterrite)




















































                A sizing exercise for our example is performed below for  (Refer to Figure 7.15.10)
              a depth type filter. A sizing chart is shown in Figure 7.15.10.  At 60 SSU, 3 psi Dp for 10 micron ‘Orlon’ cartridges, flow
              Note that the sizing must include considerations for the high  rate ¼ 3.1 GPM/cartridge
              viscosity (1,000 SSU).                                                                    60 GPM
                                                                    Number of cartridges required  ¼
                                                                                                  3:1 GPM=1 Cartridge
              Depth type filter sizing example
                                                                                               ¼  19:5 ¼ 20 Cartridges
              Given:
                                                                   2. Pressure drop @ 500 SSU operation (refer to dotted lines in
              - Light turbine oil
              - Normal viscosity ¼ 60 SSU @ 150 F                     Figure 7.15.10) at 500 SSU, 3.1 GPM/Cartridge Dp

              - Max viscosity ¼ 500 SSU @ 55 F                        exceeds 20 psi.

              - Oil flow ¼ 60 GPM                                     In the above example, to limit the filter Dp to 20 psi at 500
              - Filtration required ¼ 10 Microns                   SSU, a 2 GPM cartridge would have to have been selected. In
              - Filter material ¼ Orlon                            this case, the number of cartridges used would be:
              - Clean pressure drop ¼ 3 psi
              Determine:                                                 Number of cartridges  ¼    60 GPM
                                                                                                2 GPM=Cartridge
              - Number of filter cartridges required                                          ¼ 30
              - Pressure drop @ 500 SSU operation
              1. Determine number of cartridges