Page 47 - Handbook of Materials Failure Analysis
P. 47

40     CHAPTER 2 Failure analysis in chemical industries









                                 CT          CT           CT           CT
                                 1            2            3            4










                                                                                      P








                                   E-1         E-2         E-3          E-4










                                  Auxiliary water     Jacket water       Hot       Cold
                                  heat exchanger     heat exchanger     water     water

                         FIGURE 2.7
                         Flow sheet of a power generation and cooling system.
                                                                          With permission from Elsevier.


                          Table 2.5 Cooling System Temperature Requirements at Inlet and Outlet
                                                                  Temperature (°C)
                          Primary Cooling System Water
                                                      Inlet                Outlet

                          Jacket water                60                   80
                          Auxiliary water             40                   58
                          With permission from Elsevier.