Process chromatography 395

                                                                    AC   lOOV






                                                                   Transformer          I

















                                        18-8  Stainless







                                                      Voltage measured at the end of 4KSl's resistance
                                                      (Output)
                                                      Figure 18.1 6  Measuring circuit for semiconductor
                                                      sensor.


                                                      out  automatically  the  analytical  procedure  for
                                                      chromatographic separation, detection, and meas-
                                                      urement  of  predeterniined  constituents  of  gas-
                                                      eous mixtures.  Samples are taken  from  process
             Figure 18.15  Semiconductorsensor        streams and are presented, in a controlled manner
                                                      and under known conditions, to the gas chroma-
                                                      tograph.  Successive analyses may be made, on a
               Semiconductor  detectors  are  mainly  used  as
             low-cost devices for detection of flammable gases.   regular timed basis, on aliquots of  sample taken
                                                      from a single stream, or by use of suitable stream
             A suitable power-supply and measuring circuit is   switching valves, a single process chromatograph
             shown  in  Figure  18.16. The  main  defect of  the   may carry out automatic  sequential analyses on
             devices at present is their lack of selectivity.
                                                      process streams originating from several different
                                                      parts of the plant.
               .3.10  Properties and applications of gas   The  main  components  of  a  typical  process
             detectors                                chromatograph  system  are  shown  in  Figure
                                                      18.17. These components are: a supply of carrier
             The properties and applications of the most com-   gas to transport the sample through  the column
             monly  used  gas  detectors  are  summarized  in   and detector, a valve for introduction  of known
             Table 18.2.
                                                      quantities of sample, a chromatographic  column
                                                      to  separate  the  sample  into  its  components,  a
               .4 Process c h ro rn a t o g ra p h y   detector  and  associated  amplifier  to  sense  and
                                                      measure  the  components  of  the  sample  in  the
             On-line  or  process  gas  chromatographs  are   carrier-gas stream, a programmer  to actuate the
             instruments which incorporate  facilities to carry   operations  required  during  the  analytical
   407   408   409   410   411   412   413   414   415   416   417