Page 219 - Materials Chemistry, Second Edition
P. 219
L1644_C05.fm Page 192 Monday, October 20, 2003 12:02 PM
TABLE 5.9
Site-Specific Data: Technical Variables of the Incineration Plant
Former Current
Parameter Unit Distribution situation a situation b Reference
Mean value Mean value
Type (CV) (CV)
Electricity TJ Normal 158.56 (8.08) 149.55 (6.94) Nadal 1999
production
Waste treated t Normal 153,467(5,024) 148,450 Nadal 1999
(5,024)
Yearly h Normal 8,280 (0.05) 8,280 (0.05) Nadal 1999
working
hours
3
Flue gas Nm /h Normal 90,000 (0.05) 90,000 (0.05) Nadal 1999
volume
Transport tkm Normal 4,100,000 (0.2) 4,100,000 Weidema and
(0.2) Wesnaes
1996; STQ
1998
Plastic % Normal 13 (0.1) 13 (0.1) Weidema and
proportion Wesnaes
1996; STQ
1998
Electricity TJ Normal 1.66 (0.1) 1.66 (0.1) Weidema and
consumption Wesnaes
1996; STQ
1998
Diesel t Normal 148.8 (0.1) 148.8 (0.1) Weidema and
Wesnaes
1996; STQ
1998
Lubricant oil t Normal 2.3 (0.1) 2.3 (0.1) Weidema and
Wesnaes
1996; STQ
1998
Lime (CaO) kg Normal 0 (0) 921,000 (0.1) Weidema and
Wesnaes
1996; STQ
1998
Water m 3 Normal 19,665 (0.1) 19,665 (0.1) Weidema and
deionized Wesnaes
1996; STQ
1998
Water m 3 Normal 5,175 (0.1) 5,175 (0.1) Weidema and
refrigeration Wesnaes
1996; STQ
1998
-- continued