                                     TABLE 5.9 (continued)
                                     Site-Specific Data: Technical Variables of the Incineration Plant

                                                                       Former      Current
                                      Parameter   Unit   Distribution  situation a  situation b  Reference
                                                                     Mean value   Mean value
                                                            Type        (CV)        (CV)
                                     Water purified  m 3    Normal   7,360 (0.1)  7,360 (0.1)  Weidema and
                                                                                             Wesnaes
                                                                                             1996; STQ
                                                                                             1998
                                     Unspecified    m 3     Normal   8,122 (0.1)  33,120 (0.1)  Weidema and
                                      water                                                  Wesnaes
                                                                                             1996; STQ
                                                                                             1998
                                     Ashes treated  kg     Normal   590,000 (0.1)  3,450,000   Weidema and
                                                                                  (0.1)      Wesnaes
                                                                                             1996; STQ
                                                                                             1998
                                     Scrap treated  kg     Normal   2,740,000 (0.1)  2,740,000   Weidema and
                                                                                  (0.1)      Wesnaes
                                                                                             1996; STQ
                                                                                             1998
                                     Slag           t      Normal   42,208 (0.1)  42,208 (0.1)  Weidema and
                                                                                             Wesnaes
                                                                                             1996; STQ
                                                                                             1998
                                     a Without new filters.
                                     b With new filters.
                                     CV = coefficient of variation with the exception of electricity production and waste treated, which
                                      are expressed as normal standard deviation.



                                    mation taken from databases, Meier (1997) proposed to assume classes of normal
                                    probability distributions with the following CVs:
                                       •  For data obtained by stochiometric determination, a CV of 2% needs to
                                          be considered.
                                       •  For actual emission measurements or data computable in well-known
                                          process simulation, a CV of 10% is expected.
                                       •  For well-defined substances or summed parameters, a CV of 20% can be
                                          assumed.
                                       •  For data taken from specific compounds by an elaborated analytical
                                          method, a CV of 30% is expected.





                                    © 2004 CRC Press LLC