TABLE 5.9 (continued)
Site-Specific Data: Technical Variables of the Incineration Plant
Former Current
Parameter Unit Distribution situation a situation b Reference
Mean value Mean value
Type (CV) (CV)
Water purified m 3 Normal 7,360 (0.1) 7,360 (0.1) Weidema and
Wesnaes
1996; STQ
1998
Unspecified m 3 Normal 8,122 (0.1) 33,120 (0.1) Weidema and
water Wesnaes
1996; STQ
1998
Ashes treated kg Normal 590,000 (0.1) 3,450,000 Weidema and
(0.1) Wesnaes
1996; STQ
1998
Scrap treated kg Normal 2,740,000 (0.1) 2,740,000 Weidema and
(0.1) Wesnaes
1996; STQ
1998
Slag t Normal 42,208 (0.1) 42,208 (0.1) Weidema and
Wesnaes
1996; STQ
1998
a Without new filters.
b With new filters.
CV = coefficient of variation with the exception of electricity production and waste treated, which
are expressed as normal standard deviation.
mation taken from databases, Meier (1997) proposed to assume classes of normal
probability distributions with the following CVs:
• For data obtained by stochiometric determination, a CV of 2% needs to
be considered.
• For actual emission measurements or data computable in well-known
process simulation, a CV of 10% is expected.
• For well-defined substances or summed parameters, a CV of 20% can be
assumed.
• For data taken from specific compounds by an elaborated analytical
method, a CV of 30% is expected.