Heat pumps in the drying industry                                 145



                                       Classification of heat
                                          pump dryers




             Mode of techn.  Number of   Product  Number of  Auxiliary heat  Operation of
            process of drying  drying stages  temperature  HP stages  supply  a heat pump
                                                                     dryer

                                     Below   Above
                    Single-  Multi-  freezing                Interrupted  Cyclic
                     stage   stage           freezing
                                     point    point
                                                                  Continuous
              Serial  Continuous    Single-stage  Multi-stage
              dryers   dryers       HP dryers    dryers


                                                       by heat   Others:
                                         by convection
                                                     conductivity    -radio-frequency,
                                                                  -microwave,
                                                                  -infrared
           Fig. 4.10 Classification of heat pump dryers.


















           Fig. 4.11 SMER versus inlet temperature of the drying agent.


           configurations, depending on the relative location of air and energy flows. An estimate
           of the efficiency of heat pump dryers was carried out for some arrangements in
           Ref. [24].
              Two-stage heat pump systems are used in drying technology to achieve higher en-
           ergy efficiency and improved temperature and humidity control of the drying agent
           (Fig. 4.13).
              Figure 4.13 gives an example of a 2-stage HPD in a parallel configuration, where
           the evaporator of the first stage operates at a higher pressure relative to the evaporator
           of the second stage [25]. In terms of energy efficiency, a 2-stage heat pump can regen-
           erate more latent heat of humid air, due to a higher COP. Comparative data of the COP