Page 308 - Pipeline Risk Management Manual Ideas, Techniques, and Resources
P. 308

Modeling ideas Ill 13/285
               criteria  used number  and  location of test points  (coverage),   [Internal Corrosion Control Program]-  Evaluation of vari-
               frequency  of  test  point  readings,  variance  of  readings  from   ous internal corrosion control measures including performance
               criteria, corrective actions and timeliness,  data and activities   criteria appropriateness, inhibitor and metal loss measurement
               documentation, equipment used and its PPM, etc.   frequency  and  adequacy  for  conditions,  inhibitor  coverage
                                                          completeness, and system installation and PPM. Also includes
               0.0 pts  [Excellent CIS  Performance]-An   effective CIS  was   API 653 inspection on tanks and hot-spot protection as part of
                 conducted that exceeds all company and industry minimum   the PPM program.
                 recommended or required CIS corrosion control best practices
               2.0 pts [Adequate CIS Performance]-A   CIS was conducted   0.0 pts  [Excellent  Internal  Corrosion  Program]-A   formal
                 that  meets  all  company  and  industry  minimum  recom-   program exists that exceeds all company and industry mini-
                 mended or required CIS corrosion control best practices   mum recommended or required internal corrosion  control
               7.0 pts [Inadequate CIS Performance]-A  CIS was conducted   best practices
                 that does not meet all company and industry minimum rec-   2.0 pts  [Adequate Internal Corrosion  Program]-A   semifor-
                 ommended or required CIS corrosion control best practices   mal program exists that meets all company and industrymin-
                10.0 pts Bo CIS Conducted]-No  known CIS was conducted   imum recommended or required internal corrosion control
                 and few company and industry minimum recommended or   best practices
                 required CIS corrosion best practices are met   7.0 pts  [Inadequate Internal  Corrosion  Program]-An   infor-
                                                            mal  program  exists  that  does  not  meet  all  company  and
               [NDE  PerformanceJ-  Evaluation  of  the  effectiveness  of  a   industry minimum recommended or required internal corro-
               nondestructive  examination  (NDE)  for  identifying  system   sion control best practices
               metal loss problems and external corrosion hot spots based on   10.0 pts  [No  Internal  Corrosion  Program-No   known  pro-
               the NDE performance  criteria  used,  number and  location  of   gram exists and few company and industry minimum recom-
               inspection  points  (coverage),  frequency  of  inspection  point   mended or required internal corrosion best practices are met
               readings, variance of readings from criteria, corrective actions
               and timeliness, data and activities documentation, equipment   PDE Performance/-  Evaluation of the effectiveness of NDE
               used and its PPM. etc.                     for identifying system metal loss problems and internal corro-
                                                          sion hot  spots based  on the NDE performance  criteria used
               0.0 pts [Excellent NDE Performance]-An  effective NDE was   number and location of inspection points (coverage), frequency
                 conducted that exceeds all company and industry minimum   of inspection point readings, variance of readings from criteria.
                 recommended  or  required  NDE  corrosion  control  best   corrective actions and timeliness, data and activities documen-
                 practices                                tation, equipment used and its PPM, etc.
               2.0 pts [Adequate NDE Performance]-A  CIS was conducted
                 that  meets  all  company  and  industry  minimum  recom-   0.0 pts [Excellent NDE Performance]-An  effective NDE was
                 mended or required NDE corrosion control best practices   conducted that exceeds all company and industry minimum
               7.0 pts  [Inadequate  NDE  Performance]-A   CIS  was  con-   recommended  or  required  NDE  corrosion  control  best
                 ducted that does not meet all company and industry mini-   practices
                 mum recommended or required NDE corrosion control best   2.0 pts [Adequate NDE Performance]-A  NDE was conducted
                 practices                                  that  meets  all  company  and  industry  minimum  recom-
                10.0 pts [No NDE Conducted]--No  known NDE inspections   mended or required NDE corrosion control best practices
                 were conducted  and few company and industry minimum   7.0 pts  [Inadequate  NDE  Performance]-A   NDE  was  con-
                 recommended or required NDE corrosion best practices are   ducted that does not meet all company and industry mini-
                 met                                        mum recommended or required NDE corrosion control best
                                                            practices
               Internal corrosion mitigation               10.0 pts [No NDE Conducted]-No   known  NDE inspections
                                                            were conducted and few company and industry minimum rec-
               [Internal Couting Adequacj]-  Evaluation of various internal   ommended or required NDE corrosion best practices are met
               metal  coatings,  including coating  appropriateness,  adequacy
               for conditions, coverage completeness, installation, and PPM.   [Tank Mixer Adequacy]-  Evaluation of tank mixers, includ-
                                                          ing  appropriateness  and  adequacy  for  conditions.  effective
               0.0 pts [Excellent Internal Metal Coating]-Coating  exists that   coverage, and PPM.
                 exceeds all company and industry minimum recommended
                 or required internal coating best practices   0.0 pts  [Excellent  Mixing]-One   or  more  mixers  exist  that
               2.0 pts [Adequate Internal Metal Coating]-Coating  exists that   exceed all company and industry minimum recommended or
                 meets all company and industry minimum recommended or   required tank mixing best practices (or mixers not needed)
                 required internal coating best practices   2.0 pts  [Adequate  Mixing]-One   or more  mixers  exist  that
                7.0 pts  [Inadequate  Internal  Metal  Coating]-Coating   exists   meets all company and industry minimum recommended or
                 that does not meet all company and industry minimum rec-   required tank mixing best practices
                 ommended or required internal coating best practices   7.0 pts [Inadequate Mixing]-One  or more nilxers exist that do
                10.0 pts  [No  Internal  Metal  Coating]-No   known  coating   not meet all company and industry minimum recommended
                 exists  and  few  company  and  industry  minimum  recom-   or required mixing best practices
                 mended or required internal coating best practices are met   10.0 pts [No Mixers]-No  known mixing is performed
   303   304   305   306   307   308   309   310   311   312   313