Modeling ideas Ill 13/283
               5.0 pts  [Moderate Ground  Movement  Potentiall-Moderate   2.0 pts  [Mild  Atmospheric  Conditions]-Mild   corrosive
                 potential of  one or  more severe ground movement  events   atmospheric  conditions exist
                 occurring during an average year with the potential to cause   6.0 pts [Moderate Atmospheric Conditions]-Moderate  corro-
                 significant facility damage                sive atmospheric conditions exist
               10.0 pts [High Ground Movement Potentiall-High  potential   10.0 pts [Severe Atmospheric Conditions]-Severe   corrosive
                 of one or more  severe ground movement events occurring   atmospheric conditions exist
                 during an average year with the potential to cause significant
                 facility damage                          External corrosion susceptibility
               5.0 pts [Unknown Ground Movement Potential]
                                                          [Facility Age]-  Evaluation of station facilities (pumps, pip-
               rrufic Dumugel-  Evaluation  of  various  hazardous  traffic   ing, vessels,  equipment, and components) ages by  recording
               events, includmg moving object congestion, frequency, duration,   the last facility installation or replacement date.
               direction, mass, speed, and distance to facilities. The hazardous
               event potential  is determined by historical accident frequency,   0.0 pts [<I  yr]-Very  recent test (last facility installed?)
               severity and damage caused by  cars, trucks, rail cars, vessels,   2.0 pts [I-5 yrs]
               andor plane impacts from within and outside the station.   6.0 pts [5-10  FS]
                                                          8.0pts [l(t-20  yrs]
               0.0 pts mot Applicable]                    8.0 pts [20-30  yrs]
               2.0 pts [Low Traffic Damage Potentiall-Low  potential of one   5.0 pts [UnknownAge]
                 or more hazardous traffic events occurring during an average
                 year with the potential to cause significant facility damage   [Corrosive  Ground  Conditions]-  Evaluation  of  various
               5.0 pts  [Moderate  Traffic  Damage  Potentiall-Moderate   ground corrosivity conditions, including soil resistivity, chlo-
                 potential of one or more hazardous traffic events occurring   rides,  pH,  temperature,  moisture  level  changes,  chemicals,
                 during an average year with the potential to cause significant   transition zone, etc.
                 facility damage
               10.0 pts [HighTraffic Damage Potentiall-high potential ofone   0.0 pts [No Ground Conditions]-No  corrosive ground condi-
                 or more hazardous traffic events occurring during an average   tions exist
                 year with the potential to cause significant facility damage   2.0 pts  [Mild Ground  Conditions]-Mild   corrosive ground
               5.0 pts [UnknownTraffic Damage Potential]    conditions exist
                                                          6.0 pts  [Moderate Ground Conditions]-Moderate   corrosive
               [Activity  Leveu-  Evaluation of  the  overall  station activity   ground conditions exist
               levels, including the frequency and duration of in-station exca-   10.0 pts  [Severe  Ground  Conditions]-Severe   corrosive
               vations, facility modifications, and vehicle traffic. Controlled   ground conditions exist
               access,  third-party  facilities  present,  and  continuous  work
               inspection are also evaluated.             [Corrosive  “Hot Spot” Conditions]-  Evaluation of the pres-
                                                          ence and significance of CP interferences, including casings,
               0.0 pts [Not Applicable]                   bundled piping, foreign line crossings, interference crossings,
               2.0 pts [Low Activity  Levell-Annual  (average of  liyr) haz-   DCiAC stray currents.
                 ardous  activities occur  during an  average  year  with  the
                 potential to cause significant facility damage   0.0 pts  [No “Hot Spot” Conditions]-No   structures or  stray
               4.0  pts  [Moderate  Activity  Level]-Monthly   (average   currents are present that could interfere with CP systems, or
                 limonth) hazardous activities occur during an average year   create a corrosion hot spot, causing significant buried metal
                 with the potential to cause significant facility damage   loss
               7.0 pts  [High Activity  Levell-Weekly  (average  liwk) haz-   5.0 pts [Single “Hot Spot” Condition]-One  type of structure
                 ardous  activities occur  during  an  average  year  with  the   or stray current is present that could interfere with CP sys-
                 potential to cause significant facility damage   tems, or  create  a  corrosion hot  spot,  causing  significant
               10.0 pts  [Very  High Activity Levell-Daily   (average  l/day)   buried metal loss
                 hazardous activities occur during an average year with the   10.0 pts  [Multiple “Hot  Spot” Conditions]-Multiple   struc-
                 potential to cause significant facility damage   tures or stray currents are present that could interfere with
               5.0 pts [Unknown Activity Level]             CP systems, or create corrosion hot spots, causing signifi-
                                                            cant buried metal loss
               Corrosion algorithm variables
                                                          Internal corrosion susceptibility
               Atmospheric corrosion susceptibility
                                                          [Static  Liquids  Condition]-  Evaluation of piping facilities
               [Corrosive Atmospheric Conditions]-  Evaluation of various   where liquids are static, including piping dead-legs, pig traps
               atmospheric corrosivity conditions, including contaminants,   and out-of-service equipment. Also evaluate frequency, dura-
               temperature, moisture, chemicals, splash zones, etc.   tion, and product movements related to static conditions.
               0.0 pts  [No Atmospheric Conditions]-No   corrosive atmos-   0.0 pts [No Static Conditions]-No  corrosive static conditions
                 pheric conditions exist                    exist