Page 213 - Renewable Energy Devices and System with Simulations in MATLAB and ANSYS
P. 213

200             Renewable Energy Devices and Systems with Simulations in MATLAB  and ANSYS ®
                                                                                ®


                           TABLE 8.3
                           Wind Turbine Characteristics Used in the Simulation File

                                                       DFIG             PMSG
                           Rated grid power            2 MW             2 MW
                           Rotor diameter              82.6 m           82.6 m
                           Optimal tip-speed ratio     8.1              8.1
                           Max. power coefficient      0.37`            0.37













                           TABLE 8.4
                           Generator Parameters Used in the Simulation File

                                                       DFIG            PMSG
                           Rated grid power          2 MW             2 MW
                           Pole pairs                2                102
                           Gear ratio                95                  —
                           Rated shaft speed         1800 rpm         19 rpm
                           Stator leakage inductance  0.038 mH        0.276 mH
                           Magnetizing inductance    2.91 mH
                           Rotor leakage inductance  0.034 mH            —
                           Stator/rotor turns ratio  0.369               —












                           TABLE 8.5
                           Back-to-Back Converter Data Used in the Simulation File
                                                      DFIG              PMSG
                           Parallel converters       2                 4
                           Rated active power        400 kW            500 kW
                           DC-link voltage           1150 V            1150 V
                           Switching frequency       2 kHz             2 kHz
                           Grid-side converter
                           Rated output voltage      704 V             704 V
                           Filter inductance         0.5 mH            0.15 mH
                           Generator-side converter
                           Rated output voltage      560 V             760 V
   208   209   210   211   212   213   214   215   216   217   218