The Practical  Pumping  Handbook  __-


      Pipe Size     Length of Pipe      Hf  per l OOft      Friction Loss
      3 inch        70  feet            8.90  feet          6.23  ft.
      4  inch       20  feet            2.27  feet          0.454  ft.
                                        Piping Losses       6. 684feet


      Valves and  Fittings  Losses  based  on  a Flow  Rate  of 200  gpm
      (from  Resistance  Coefficient Tables  and  Friction  Loss Tables)
      Item                     K factor  V2/2g   Hf  per   Qty   Total Hf
                                                 fixture
      4"  flanged  Foot Valve   0.8     0.395    0.316     1    0.316  ft.
      4"  Flanged  Long rad.  Elbow  0.22   0.395   0.0869   1   0.0869  ft.
      3"  Flanged  Gate Valve   0.25    1.17     0.2925    1    0.29  ft.
      3"  Flanged  Check Valve   0.2    1.17     0.234     1    0.23  ft.
      3"  Long  Rad.  Flanged  Elbow0.26   1.17   0.3042   2    0.6084  ft.
                                        Valves and Fitting Losses   1.5313 ft.

      Total Friction Losses  =  6.684 + 1.5313  =  8.2153ft.
      Implementing  a  10% Safety Factor  = 8.2153  x  1.1
                                Therefore  Total  Friction  Losses  (Hf)  = 9.0  feet


      H   =   Hs     +   Hsd   +   Hv     +   Hf
          =   60     +   0    +    0.775   +   9.0
          =   70  feet

      Therefore  design  operating  condition  =  200  gpm  @ 70  feet  of  Head