Page 67 -
P. 67

The  Practical  Pumping  Handbook  -   ~   ~-~


      Friction Loss  (Hf)
      Piping Losses  based on  a Flow Rate  of 340  gpm
      (from Friction Loss Tables)
      Pipe Size      Length of Pipe     Hf  per 100ft       Friction Loss
      4  inch        130  feet          6.19  feet          8.047 ft.
      6  inch       25  feet            0.806               0.2015  ft.
                                        Piping Losses       8.2485 feet


      Valves and Fittings  Losses based on a Flow Rate  of 340  gpm
      (from Resistance  Coefficient Tables  and Friction Loss Tables)
      Item                     K factor  V2/2g   Hf  per   Qty   Total Hf
                                                 f~tu~
      6"  flanged  Gate Valve   0.11    0.222    0.02442        0.04884  ft.
      6"  flanged Std.  Elbow   0.29    0.222    0.06438        0.12876  ft.
      4"  flanged  Gate Valve   0.16    1.14     0.1824         0.3648  ft.
      4"  flanged  Check Valve   0.2    1.14     0.228          0.228  ft.
      4"  long rad.  Flanged  Elbow  0.22   1.14   0.2508       0.2508  ft.
                                     Valves and Fitting Losses   1.0212feet

      Total Friction Losses = 8.2485 + 1.0212 = 9.2697ft.


      Implementing a  10% Safety Factor = 9.2697  x  1.1

                              Therefore  Total  Friction  Losses  (Hf)  = 10.2  feet

      H        Hs   +   Hsd  +   Hv.     +   Hf
               40   +   0    +   0.918   +   10.2
           m
               51.118  feet

      Therefore  design  operating  condition  =  340  gpm  @ 51  feet  of Head