Page 357 - The Tribology Handbook
P. 357

Single line-resistance (oil only)
                 Operation: ii  motor  driven  piston  pump  discharges  a
                 predetermined  volume  of  oil  at controlled  intervals  to  a
                 single main  line. Flow  units  in, the system proportion  the
                 total  pump discharge according to  the relative  resistance
                 of the units.
                   Care needs to be taken in the selection of components to
                 ensure  each  bearing  receives  the  required  volume  of
                 lubricant; as a  result, this type of system is used predomi-
                 nantly for original equipment application.

                 Applications: Machine tools  and textile machinery
                 Specification:

                 Outlets:  1-100  (0.01-1  ml)
                 Pressure: 300-500  kN/rn2
                 Lubricants:  10-1800  cSt  (Oil only)
                 Failure warning: line pressure monitoring.
                 Cost factor: Low.

                                                                                  Figure 15.8 Pump















                               BEARINGS


                              Figure  15.7  Schematic


















                                                                                Figure 15.9  Flow unit









                                                              15.3