Page 119 - Wire Bonding in Microelectronics
P. 119

98     Cha pte r  F o u r








                        Friction rewelding












              FIGURE 4-14  An example of a gold ball strongly bonded to gold metallization
              that underwent friction rewelding to the pad. Note also the gross deformation
              of the ball resulting from shear testing a strongly welded ball bond. This TS bond
              was made from 25 µm (1 mil) diameter wire. (After Weiner [4-35]; © IEEE.)



                 Gold-to-gold friction rewelding: Shearing Au bonds on Au substrates
                 can lead to an unusual interference. Gold is capable of friction weld-
                 ing to Au surfaces at room temperatures. An SEM photograph of a
                 deformed Au ball and Au bonding pad showing the results of mul-
                 tiple friction rewelding is given in Fig. 4-13. Rewelding problems
                 may be eliminated by using a shear tool design that is slightly
                 ground-back from the forward edge. This will lift the ball, pre-
                 venting rewelding [4-20]. Friction rewelding seldom occurs while
                 shearing bonds on Al metallized IC pads, where the small size

                 of the pad, as well as the passivation surface film adjacent to the
                 pad, prevents it.
                 Interferences when shearing bonds on thick fi lms  (and a method of
                 determining weak metallization adhesion problems): Several potential
                 interferences can occur when shearing ball bonds on thick-fi lm met-
                 allization. One would normally assume that balls of a given diam-
                 eter would yield shear forces somewhat lower when bonded to thick

                 fi lms than when bonded to thin films, since thick films contain pits

                 and voids, and, in some cases, glass or oxide occlusions on the sur-
                 face. There have been a number of shear test studies of ball bonds
                 on thick-fi lm metallization in the literature [4-21, 4-22, 4-23].
                    However, there was not enough information given on the
                 welded ball size, or the actual welded area, to compare directly
                 with the extensive laboratory data published on thin films. One
                 might expect to use the same experimental procedure in shearing
                 bonds made to thick films as for thin films. However, the thick films
                 themselves are often higher than the recommended vertical posi-
                 tion of the tool above the substrate when set for shearing bonds on
   114   115   116   117   118   119   120   121   122   123   124