Page 463 - Subyek Teknik Mesin - Forsthoffers Best Practice Handbook for Rotating Machinery by William E Forsthoffer
P. 463

Be st Practice 7 .29          Lube, Seal and Control Oil System Best Practices





















       Fig 7.29.8   Modularized oil console arrangement (Courtesy of Fluid
       Systems, Inc.)




                                                            Fig 7.29.10   Modularized oil console arrangement (Courtesy of Fluid
                                                            Systems, Inc.)


                                                            Horizontal console (no components on the
                                                            reservoir)
                                                            Please refer to Figure 7.29.9. This console arrangement is fairly
                                                            typical for a critical equipment lubrication system. Note the
                                                            positions of components affording ample space for maintenance
                                                            and equipment calibration. In addition, note the placement of
                                                            interconnecting piping, thus allowing for maximum mobility on
                                                            the console.

                                                            Reservoir integral with component
                                                            Refer to Figure 7.29.10. This arrangement is frequently used
       Fig 7.29.9   Horizontal oil console arrangement (Courtesy of G.J. Oliver,
       Inc.)                                                in restricted space locations or could be the result of an at-
                                                            tempt by the original equipment vendor to minimize cost.
                                                            Careful scrutiny of arrangement design early during the project
                                                            can avoid problems. Note from Figure 7.29.10 that even
       a premium. This system should be reviewed thoroughly in the  though all components are mounted on the reservoir, acces-
       design phase to optimize accessibility. Note that even though  sibility is maximized to components. In this case, the reservoir
       space is minimal, major components can be arranged such that  was mounted approximately three feet below grade, thus
       accessibility is possible.                           allowing all components to be within easy maintenance reach.