Requirernents Specificcitiori   27



                                            OIL OUT
                                                     0
                                      \E
                               x
                              [SEE NOTE 3)





                               FILTER                    FILTER












                                                                   , [SEE
                                                                   NOTES 1 AND  2)










                              +q-i?TJ  -

                                  NORMALLY
                                    OPEN


                                            OIL IN
                          NOTES:
                          1.  Option A-l8a: The purchaser may specify a bypass oil line and a constant-temperature control valve.
                          2.  Option A-18b: It the  iaildosed (FC) feature oi the  direct-acting temperature control valve  is not
                          acceptable. the purchasea may specify a valve with a iail-locked (FL) feature.
                          3.  Option A-18c: The purchaser may specify a high-temperature switch (TSH) and/or a low-temperature
                          switch  (TSL).
                          4.  Option A-l8d: The purchaser  may specify light  shutoff requiring spectacle blinds.
                   Figure 1-16.  Twin oil coolers and filters with a single continuous flow transfer valve.
                   (Courtesy American Petroleum Institute.)