Page 173 - Industrial Process Plant Construction Estimating and Man Hour Analysis
P. 173

Coal-fired power plant Chapter  8 149


             8.8.3  Tubes, down comers, accessories, burner, soot blowers,
             economizer sheet 3


             Description                                        MH       Unit
             Headers                                            15.00    Ton
             Tubes—make up or supply                            2.00     EA
             Tubes—riser                                        1.65     EA
             Weld tubes to header stubs—(4 < BW   4-1/2 TIG) (2001–2600) psi  6.50  EA
                                   00
             Install down comer                                 24.00    Ton
             Diameter weld, girth—field pipe weld               1.20     DI
             Diameter weld, girth—field pipe weld               1.20     DI
             Diameter weld, girth—field pipe weld               1.20     DI
             Floor and hopper support steel                     28.00    Ton
             Suspension steel                                   30.00    Ton
             Backstays                                          36.00    Ton
             Erect casing panels and assemblies                 15.00    EA
             Fit and weld casing seams                          0.55     LF
             Burner wine box—primary, secondary, and tertiary   75.00    Ton
             Hoppers                                            95.00    Ton
             Doors and frames                                   10.00    EA
             Seals                                              190.00   Ton
             Expanded metal lathe                               0.08     SF
             Closure plates                                     95.00    Ton
             Coal, volumetric, or gravimetric feeders           16.00    Ton
             DRB-4Z low Noᵪ coal burner                         240.00   EA
             Dual zone Noᵪ port (overfired air system)          200.00   EA
             Inter tube burners include blocks, tips, and riffle casings  18.00  Ton
   168   169   170   171   172   173   174   175   176   177   178