Page 419 - Industrial Wastewater Treatment, Recycling and Reuse
P. 419

An Introduction to Biological Treatment and Membrane Filtration  391




























              Figure 9.12 Aqua EMBR pilot plant.

              Table 9.5 Biological parameters
              Sr. No       Parameters                Unit         Value

              1            Aeration tank volume      m 3           20
              2            HRT                       hrs           18
              3            MLSS                      mg/L          14,000-18,000
              4            DO                        mg/L          2.0
              5            SRT                       day           38


                 Feed and product water quality was monitored by analysis of COD,
              BOD, pH, alkalinity, and turbidity, while biological parameters such as
              MLSS, SVI, and DO were measured. All the analytical parameters were
                                                            st
              computed by standard procedures given in APHA, 21 edition. An illustra-
              tion of the actual installed plant is shown in Figure 9.12. The biological
              parameters maintained and operating conditions for the plant are given in
              Tables 9.5 and 9.6 respectively.



              9.11 RESULTS AND DISCUSSION

              Initially, a single-stage bioreactor process was proposed for the treatment of
              wastewater. It was observed that by maintaining biological parameters, more
              than a 90% COD reduction can be achieved as required for the discharged