Page 470 - Instrumentation Reference Book 3E
P. 470

Power measurement 453

             Table 20.7  Comparison of digital voltmeter specifications
                           ~
                             34-digit multimeter   5  -digit intelligent   8 f -digit Stunduvds
                               (Fluhe 8026E)         niiibinzeter.       Lnbomtoq. D I'M
                                                     (Thuviby 1905.4)    (Soinrtroiz 7081)
             D.c. voltage ranges   199.9mV-1000V   210.000mV-1100.00V   0.1 V-lO0OV
             Typical accuracy   &(O.l%R + 1 digit)   I (0.015'1'0R + O.O015%S   Short-term stability
                                                     +2  digits)         h(1.2ppm R + 0.3ppm S)
             Input impedance   10 MQ on all ranges   > 1 GR on lowest two   > 10 GR  on 3 lowest ranges
                                                     ranges              10 Ma on remainder
                                                     10 MR on remainder
             A.c. voltage ranges   1 99.9 mV-7 50 rms   310.00mV-750V  rms   0.1 V-1000  V rms
             Type            True rms sensing      Mean sensinghs       True rms sensing crest
                               crest factor 3:l      calibrated for sinusoid   factor 5.1 short-term
                                                                         stability
             Typical accuracy   f( 1VnR + 3 digits)   f (2%R + 10 digits)   +(0.05%R 1 0.03n/'S)
             Frequency range   45 Hz-10  kHz       45 Hz-20  kHz        10Hz-1001~Hz
             Input impedance   10 MQ 11 100 pF      10MR1147pF          1MRI/100pF
             D.c. current ranges   1.999mA-1.999A   210.000  PA-2100.00mA
             Typical accuracy   i(0.75YnR + 1 digit)   &(O.l%R+ O.O015%S+2
                                                     digits)
             Voltage burden   0.3 V max. on all ranges   0.15 V max. on all ranges   Not applicable
                             except  1.999 A range.   except 2100mA range.
                             Max. burden on 1.999 A   Max. burden on
                             range 0.9 V             2100mA range 0.75V
             A.c. current ranges   1.999n-u-1.999A   210.00 PA-2100.0  mA
             Type            True rms sensing      Mean sensinglrms
                               crest factor 3.1      calibrated for sinusoid
             Typical accuracy   f(1.5%R + 2 digits)   i(0.30/oR + 5 digits)   Not applicable
             Frequency range   45 Hz-1  kHz        45 Hz-500  Hz
             Voltage burden   0.3 V max. on all ranges   0.25 V max. on all ranges
                               except 1.999 A range.   except 2100.0mA range.
                               Max. burden on  1.999A   Max burden on
                               range 0.9V            2100.0mA range 0.75V
             Resistance ranges   199.9 0-19.99  MR   2 IO ,000 R-2  1.000 MR   0.1 id-lOOOMR
             Typical accuracy   i(O.l%R + 1 digit)   k(O.O4%R + O.O015%S + 2  Short-term stability (3ppm
                                                     digits)             R + 0.4 ppm S)
             Current employed   Max. current 0.35 mA   Max. current 1 mA on   Max. current 1  mA on 0.1, 1
                               on 199.90 range       210.000R range      and  10 kR ranges
             Speed of reading                      3 per second         100 per second to  1 pel
                                                                        51.2s

             Common-mode     ,100dB  at d.c.. 50Hz, and   > 120 dB at d.c. or 50 Hz   Effective CMR
              rejection ratio   60 Hz with  1 kR unbalance               [CMR + SMR] with  1 ki2
                               for d.c. ranges                           unbalance
                             >60 dB for 50 and 60 Hz                    54-  84 digit >140dB at
                               with  1 kR unbalance on                   -50(6b) Hz
                               ax. ranges                                        >I20 dB at
                                                                         400 Hz
                                                                        for ax. measurement
                                                                         >40dB at 50(60) Hz
             Series mode rejection   >60dB at 50Hz or 60Hz   >60 dB at 50 Hz   5!  - 8;  digits
                                                                        /70  dB at 50(50) or 400 Hz
             Continued
   465   466   467   468   469   470   471   472   473   474   475