Page 153 - Industrial Process Plant Construction Estimating and Man Hour Analysis
P. 153

128  Industrial process plant construction estimating and man-hour analysis


            7.32 Lube oil system (pump and tanks) installation man-hour

            Facility—diesel power plant          Actual        Estimate
            Description                          MH      BM   IW    PF   MH

            Lube oil service tank 1000gal        20      0    0     0    0
            Dress out—filling, suction, drain, vent, overflow  60  0  0  0  0
            Instrument                           20      0    0     0    0
            Clean lube oil tank 12,000gal        40      0    0     0    0
            Dress out—filling, suction, drain, vent, overflow  60  0  0  0  0
            Instrument                           24      0    0     0    0
            Flushing filter                      10      0    0     0    0
            Flex rubber bellows                  84      0    0     0    0
            Bolt up                              126     0    0     0    0
            Used lube oil tank 4000gal           20      0    0     0    0
            Dress out—filling, suction, drain, vent, overflow  60  0  0  0  0
            Instrument                           24      0    0     0    0
            Pipe bridge platform with stairs     360     0    0     0    0
            Pipe supports                        340     0    0     0    0
            AB (PS)                              260     0    0     0    0
            Lube oil pump unit                   40      0    0     0    0
            Equipment installation man-hours     1548    0    0     0    0




            7.33 Installation of utility water estimate data


            Description                               MH                Unit
            DAD/901 oil water transfer pump 342#      40.0              EA
            Bolt down                                 4.0               EA
            NOx controller                            4.0               EA
            SEN dosing box                            4.0               EA
            IC pipe                                   2.0               LF
            Bolt up                                   3.1               EA
            Flex rubber bellows                       4.0               EA
            Bolt up                                   3.2               EA
   148   149   150   151   152   153   154   155   156   157   158