Page 253 - Renewable Energy Devices and System with Simulations in MATLAB and ANSYS
P. 253

240             Renewable Energy Devices and Systems with Simulations in MATLAB  and ANSYS ®
                                                                                ®


                  TABLE 9.6
                  DC-Excited Synchronous Generator Parameters and Features (7.6 MW,
                  11 rpm, 3.6 kV)
                  Dsi (m)                 11.768          Stator inner diameter
                  Dso (m)                 12              Stator outer diameter
                  Dri (m)                 11.491          Rotor inner diameter
                  Lg (m)                  0.98            Magnetic core length
                  hag (mm)                3.25            Air-gap height
                  hag max /hag            1.2             Maximum air gap/minimum air gap
                  q1                      2               Number of slots per phase per pole
                  Turns per coil          12
                  Parallel path           180
                  hst (mm)                25.5            Stator slot total height
                  hs1 (mm)                20              Height of stator slot filled with copper
                  Ws (mm)                 14.7            Width of the stator slots
                  So (mm)                 7.              Stator slot opening
                  wrt (mm)                105             Rotor pole width
                  wrps (mm)               170.4           Rotor pole shoe width
                  mg (ton)                80.0            Active material weight
                  Etan (%)                94.54           Efficiency at pure resistive power factor
                  Pcun (kW)               237.61          Stator copper losses
                  Pex0n (kW)              34.68           Excitation, load losses
                  Pexn (kW)               84.13           Excitation losses at rated resistive load
                  Pfen (kW)               96.69           Iron-rated losses
                  Stator linkage flux (Wb)  2.96/2.79     Analytical/FEM
                  Xd (pu)                 0.878/0.824     d-axis reactance per unit (analytical/fem)
                  Xq (pu)                 0.586/0.443     q-axis reactance per unit (analytical/fem)







                                   R
                            3.5    0.8 RL
                                   0.6 RL
                                   L
                             3     0.8 RC
                          Excitation current (pu)  1.5 2
                                   0.6 RC
                                   C
                            2.5






                            0.5 1

                             0
                                     0.2     0.4    0.6     0.8      1      1.2
                                                Load current (pu)

            FIGURE 9.27  Excitation current versus load current of DCE-SG (R, L, and C are resistive, inductive, and
            capacitive loads, and RL and RC are resistive inductive and resistive capacitive loads).
   248   249   250   251   252   253   254   255   256   257   258